A multicenter study to evaluate harmonization of assays for N-terminal propeptide of type i procollagen (PINP): A report from the IFCC-IOF Joint Committee for Bone Metabolism
Journal article
Cavalier, Etienne, Eastell, Richard, Jørgensen, Niklas Rye, Makris, Konstantinos, Tournis, Symeon, Vasikaran, Samuel, Kanis, John A., Cooper, Cyrus, Pottel, Hans and Morris, Howard A.. (2019). A multicenter study to evaluate harmonization of assays for N-terminal propeptide of type i procollagen (PINP): A report from the IFCC-IOF Joint Committee for Bone Metabolism. Clinical Chemistry and Laboratory Medicine. 57(10), pp. 1546 - 1555. https://doi.org/10.1515/cclm-2019-0174
Authors | Cavalier, Etienne, Eastell, Richard, Jørgensen, Niklas Rye, Makris, Konstantinos, Tournis, Symeon, Vasikaran, Samuel, Kanis, John A., Cooper, Cyrus, Pottel, Hans and Morris, Howard A. |
---|---|
Abstract | Background Biochemical bone turnover markers (BTM) are useful tools to assess bone remodeling at the cellular level. N-terminal propeptide of type I procollagen (PINP) has been recommended as a reference marker for bone formation in research studies. Methods We describe the results of a multicenter study for routine clinical laboratory assays for PINP in serum and plasma. Four centers (Athens, Greece [GR], Copenhagen, Denmark [DK], Liege, Belgium [BE] and Sheffield, United Kingdom [UK]) collected serum and plasma (EDTA) samples from 796 patients presenting to osteoporosis clinics. Specimens were analyzed in duplicate with each of the available routine clinical laboratory methods according to the manufacturers’ instructions. Passing-Bablok regressions, Bland-Altman plots, V-shape evaluation method and the concordance correlation coefficient for PINP values between serum and plasma specimens and between methods were used to determine the agreement between results. A generalized linear model was employed to identify possible variables that affected the relationship between the methods. Results We showed that both EDTA plasma and serum were suitable for PINP determination. We observed a significant proportional bias between Orion radioimmunoassay and the automated methods for PINP (Roche Cobas and IDS iSYS), which both gave very similar results. The multivariate model did not improve the excellent correlation that was observed between the methods. Conclusions Harmonization of PINP assays is possible by applying a correction factor or correctly assigning the values of the calibrators. This work will benefit from further collaboration between assays manufacturers and clinical laboratory professionals. |
Keywords | bone marker; bone turnover; markers; harmonization; N-terminal propeptide of type I; procollagene; propeptide of type I procollagen (PINP). |
Year | 2019 |
Journal | Clinical Chemistry and Laboratory Medicine |
Journal citation | 57 (10), pp. 1546 - 1555 |
Publisher | Walter de Gruyter GmbH |
ISSN | 1434-6621 |
Digital Object Identifier (DOI) | https://doi.org/10.1515/cclm-2019-0174 |
Scopus EID | 2-s2.0-85065968674 |
Page range | 1546 - 1555 |
Research Group | Mary MacKillop Institute for Health Research |
Publisher's version | File Access Level Controlled |
Place of publication | Germany |
https://acuresearchbank.acu.edu.au/item/85q95/a-multicenter-study-to-evaluate-harmonization-of-assays-for-n-terminal-propeptide-of-type-i-procollagen-pinp-a-report-from-the-ifcc-iof-joint-committee-for-bone-metabolism
Restricted files
Publisher's version
125
total views0
total downloads0
views this month0
downloads this month