Surface-scribed transparency-based microplates
Journal article
Li, Xin Ye, Cheong, Brandon Huey-Ping, Somers, Anthony, Liew, Oi Wah and Ng, Tuck Wah. (2013). Surface-scribed transparency-based microplates. Langmuir. 29(2), pp. 849 - 855. https://doi.org/10.1021/la304394s
Authors | Li, Xin Ye, Cheong, Brandon Huey-Ping, Somers, Anthony, Liew, Oi Wah and Ng, Tuck Wah |
---|---|
Abstract | Transparency sheets, which are normally associated with use on overhead projectors, offer lowered costs and high amenability for optical diagnostics in microplate instrumentation. An alternative microplate design in which circles are scribed on the surface of the transparency to create the boundaries to hold the drop in place is investigated here. The 3D profile of the scribed regions obtained optically showed strong likelihood of affecting three-phase contact line interactions. During dispensation, the contact angle (≈95°) was larger than the drop advancing state (≈80°) due to a period of nonadhesion, where the contact angle later reduced to the drop advancing state followed by increase in the liquid area coverage on the substrate. It was established that 50 μL was needed to fill the well fully, and the maximum volume retainable before breaching was 190 μL. While the tilt angle needed for displacement reduced significantly from 50 to 95 μL, this was markedly better than nonscribed surfaces, where tilt angles always had to be kept to within 30°. It was found that there was greater ability to fill the well with smaller volumes with dispensation at the center. This was attributed to the growing contact line not meeting the scribed edge in parallel if liquid was dispensed closer to it, wherein pinning reduction in some directions permitted liquid travel along the scribed edge to undergo contact angle hysteresis. Fluorescence measurements conducted showed no performance compromise when using scribed transparency microplates over standard microplates. |
Keywords | contact angle; liquids; fluorescence; optical properties; hydrophobicity |
Year | 2013 |
Journal | Langmuir |
Journal citation | 29 (2), pp. 849 - 855 |
Publisher | American Chemical Society |
ISSN | 0743-7463 |
Digital Object Identifier (DOI) | https://doi.org/10.1021/la304394s |
Scopus EID | 2-s2.0-84872546404 |
Page range | 849 - 855 |
Research Group | School of Behavioural and Health Sciences |
Publisher's version | File Access Level Controlled |
Place of publication | United States of America |
https://acuresearchbank.acu.edu.au/item/86z7x/surface-scribed-transparency-based-microplates
Restricted files
Publisher's version
56
total views0
total downloads1
views this month0
downloads this month