Point-of-care testing of activated clotting time in the ICU: Is it relevant?
Journal article
Brown, Ellenora, Clarke, Jody, Edward, Karen-Leigh and Giandinoto, Jo-Ann Michelle. (2016). Point-of-care testing of activated clotting time in the ICU: Is it relevant? British Journal of Nursing. 25(11), pp. 608 - 612. https://doi.org/10.12968/bjon.2016.25.11.608
Authors | Brown, Ellenora, Clarke, Jody, Edward, Karen-Leigh and Giandinoto, Jo-Ann Michelle |
---|---|
Abstract | Background: Over the past 50 years there have been significant advances in both the clinical techniques and equipment used in the intensive care environment. One traditionally used point-of-care test is activated clotting time (ACT), a coagulation test primarily used during cardiopulmonary bypass surgery to monitor the anticoagulation effects of heparin. The ACT test has since emerged into the intensive care environment to guide clinical assessment and management of haemostasis in postoperative cardiac patients. Objectives: The aim of this integrative systematic review was to critique the available research evaluating the effectiveness of ACT point-of-care testing in the intensive care unit for adult patients following cardiopulmonary bypass and cardiac surgery and any impacts this may have on nursing care. Methods: A systematic search of Medline, CINAHL and PubMed was undertaken. Results: The search identified five research papers reporting on the use of ACT point-of-care testing in the intensive care unit for adult cardiac surgical patients. Meta-analysis was not performed due to the lack of homogeneity between the papers included. Conclusions: There was a lack of clear evidence for the use of the ACT point-ofcare test after cardiac surgery in the intensive care environment. This review has highlighted that conventional laboratory tests are generally more accurate and reliable than this point-of-care test in guiding nursing care management. |
Keywords | activated clotting time; point-of-care testing; intensive care unit; nursing assessment; systematic review |
Year | 2016 |
Journal | British Journal of Nursing |
Journal citation | 25 (11), pp. 608 - 612 |
Publisher | Mark Allen Holdings Limited |
ISSN | 0966-0461 |
Digital Object Identifier (DOI) | https://doi.org/10.12968/bjon.2016.25.11.608 |
Scopus EID | 2-s2.0-84974691405 |
Page range | 608 - 612 |
Research Group | School of Nursing, Midwifery and Paramedicine |
Publisher's version | File Access Level Controlled |
Place of publication | United Kingdom |
Editors | I. Peate |
https://acuresearchbank.acu.edu.au/item/87300/point-of-care-testing-of-activated-clotting-time-in-the-icu-is-it-relevant
Restricted files
Publisher's version
150
total views0
total downloads4
views this month0
downloads this month