Plasma TIMP-4 predicts left ventricular remodeling after acute myocardial infarction
Journal article
Weir, Robin A. P., Clements, Suzanne, Steedman, Tracey, Dargie, Henry J., McMurray, John J. V., Squire, Iain B. and Ng, Leong L.. (2011). Plasma TIMP-4 predicts left ventricular remodeling after acute myocardial infarction. Journal of Cardiac Failure. 17(6), pp. 465 - 471. https://doi.org/10.1016/j.cardfail.2011.02.002
Authors | Weir, Robin A. P., Clements, Suzanne, Steedman, Tracey, Dargie, Henry J., McMurray, John J. V., Squire, Iain B. and Ng, Leong L. |
---|---|
Abstract | Background: Alterations in the balance between matrix metalloproteinases and their endogenous tissue inhibitors (TIMPs) are associated with left ventricular (LV) remodeling after acute myocardial infarction (AMI). No relationships have been identified between TIMPs and serial postinfarction change in LV function. Methods and Results: Plasma concentrations of TIMP-1, -2, -4 were measured at baseline (mean 46 h) and at 24 weeks in 100 patients (age 58.9 ± 12 years, 77% male) admitted with AMI and LV dysfunction, with cardiac magnetic resonance imaging at each time point. TIMP-1 concentration was reduced, whereas TIMP-2 and -4 concentrations were elevated at baseline compared with a reference control population. TIMP-1 decreased and TIMP-2 increased significantly over time; there was an incremental trend in TIMP-4 concentration. Baseline TIMP-4 correlated with change in LV end-systolic volume index (∆LVESVI; r = 0.24; P = .023) and change in LV end-diastolic volume index (∆LVEDVI; r = 0.25; P = .015). ∆TIMP-4 also correlated with ∆LVESVI and with ∆LVEDVI, as did ∆TIMP-2. On multivariable analysis, baseline TIMP-4 concentration was an independent predictor of ∆LVESVI. Conclusions: Plasma TIMP-4 concentration, measured early after AMI, may assist in the prediction of LV remodeling and therefore in the assessment of prognosis. Further study of the role of the TIMPs in the pathophysiology of postinfarction remodeling is warranted. |
Keywords | Cardiac magnetic resonance; TIMP-1; TIMP-2; BNP |
Year | 2011 |
Journal | Journal of Cardiac Failure |
Journal citation | 17 (6), pp. 465 - 471 |
Publisher | Churchill Livingstone |
ISSN | 1071-9164 |
Digital Object Identifier (DOI) | https://doi.org/10.1016/j.cardfail.2011.02.002 |
Scopus EID | 2-s2.0-79957796804 |
Page range | 465 - 471 |
Research Group | Mary MacKillop Institute for Health Research |
Publisher's version | File Access Level Controlled |
Place of publication | United States |
https://acuresearchbank.acu.edu.au/item/89v31/plasma-timp-4-predicts-left-ventricular-remodeling-after-acute-myocardial-infarction
Restricted files
Publisher's version
85
total views0
total downloads1
views this month0
downloads this month