Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy

Journal article


Ward, Leigh, Winall, Ann, Isenring, Elizabeth, Hills, Andrew, Czerniec, Sharon, Dylke, Elizabeth and Kilbreath, Sharon. (2011). Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy. International Journal of Gynecological Cancer. 21(2), pp. 409 - 418. https://doi.org/10.1097/IGC.0b013e31820866e1
AuthorsWard, Leigh, Winall, Ann, Isenring, Elizabeth, Hills, Andrew, Czerniec, Sharon, Dylke, Elizabeth and Kilbreath, Sharon
Abstract

Objective: The aim of the present study was to determine if the ratio of extracellular fluid (ECF), including the lymph, to that of intracellular fluid (ICF), as measured by bioimpedance spectroscopy (BIS), could be used to assess bilateral lymphedema (LE). Background: The presence of LE is commonly determined as an increase in tissue volume due to the presence of excess lymph relative to the volume of a comparable unaffected body region or to comparative normative data. However, in bilateral LE of the limbs, a comparable body region, the contralateral limb, is also affected, precluding normalization. An alternative is to normalize the increase in lymph volume, as ECF, to that of ICF volume. Methods: Extracellular/intracellular fluid ratios, expressed as the ratio of intracellular impedance (Ri) to extracellular impedance (R0), for the limbs of 277 female and 224 male controls were determined from an accumulated database of impedance data. Equivalent data were obtained for an opportunistic cross-sectional sample of 37 female and 5 male participants with bilateral LE of the legs. The ratios of Ri/R0 in the lymphedematous legs of the affected participants were compared with the equivalent ratios in the unaffected arms of the same participants and with those of the controls using box plots and visualized as bivariate data using tolerance ellipses. Results: Despite Ri/R0 ratios varying with age, sex, and limb dominance, comparison of the ratio for affected legs (normalized to the ratio in the unaffected arms) with equivalent ratios observed in a control population (as bivariate tolerance plots) was capable of discriminating between 70% and 89% of the participants with LE. Conclusions: Bioelectrical impedance spectroscopy and determination of Ri/R0 ratios as indices of ECF/ICF ratios holds promise for the semiquantitative assessment of bilateral LE.

Year2011
JournalInternational Journal of Gynecological Cancer
Journal citation21 (2), pp. 409 - 418
PublisherLippincott Williams & Wilkins
ISSN1048-891X
Digital Object Identifier (DOI)https://doi.org/10.1097/IGC.0b013e31820866e1
Scopus EID2-s2.0-79956096438
Page range409 - 418
Research GroupSchool of Allied Health
Publisher's version
File Access Level
Controlled
Place of publicationUnited Kingdom
Permalink -

https://acuresearchbank.acu.edu.au/item/8q5vz/assessment-of-bilateral-limb-lymphedema-by-bioelectrical-impedance-spectroscopy

Restricted files

Publisher's version

  • 76
    total views
  • 0
    total downloads
  • 1
    views this month
  • 0
    downloads this month
These values are for the period from 19th October 2020, when this repository was created.

Export as

Related outputs

Estimation of Arm Adipose Tissue Quotient Using Segmental Bioimpedance Spectroscopy
Ruben Buendia, T. Essex, Sharon Kilbreath, Sharon Czerniec, Elizabeth Dylke and Leigh C. Ward. (2018). Estimation of Arm Adipose Tissue Quotient Using Segmental Bioimpedance Spectroscopy. Lymphatic Research and Biology. 16(4), pp. 377-384. https://doi.org/10.1089/lrb.2017.0050
Does lymphedema severity affect quality of life? Simple question. Challenging answers
Teresa S. Lee, Carol M. Morris, Sharon Czerniec and Andrea J. Mangion. (2018). Does lymphedema severity affect quality of life? Simple question. Challenging answers. Lymphatic Research and Biology. 16(1), pp. 85-91. https://doi.org/10.1089/lrb.2016.0049
A patient-based self-examination survey for staging the severity of lymphoedema
Morris, Carol M., Lee, Teresa S., Czerniec, Sharon A. and Mangion, Andrea J.. (2017). A patient-based self-examination survey for staging the severity of lymphoedema. Journal of Lymphoedema. 12(1), pp. 10 - 15.
Breast Cancer-Related Arm Lymphedema: Fluctuation over Six Months and the Effect of the Weather
Czerniec, Sharon Anne, Ward, Leigh and Kilbreath, Sharon. (2016). Breast Cancer-Related Arm Lymphedema: Fluctuation over Six Months and the Effect of the Weather. Lymphatic Research and Biology. 14(3), pp. 148 - 155. https://doi.org/10.1089/lrb.2015.0030
Assessment of segmental arm soft tissue composition in breast cancer-related lymphedema : A pilot study using dual energy X-ray absorptiometry and bioimpedance spectroscopy
Czerniec, Sharon Anne, Ward, Leigh, Meerkin, Jarrod and Kilbreath, Sharon. (2015). Assessment of segmental arm soft tissue composition in breast cancer-related lymphedema : A pilot study using dual energy X-ray absorptiometry and bioimpedance spectroscopy. Lymphatic Research and Biology. 13(1), pp. 33 - 39. https://doi.org/10.1089/lrb.2014.0033
Assessment of breast cancer-related lymphedema : A comparison of moisture meter and spot bioimpedance measurement
Czerniec, Sharon Anne, Ward, Leigh and Kilbreath, Sharon. (2015). Assessment of breast cancer-related lymphedema : A comparison of moisture meter and spot bioimpedance measurement. Lymphatic Research and Biology. 13(1), pp. 10 - 19. https://doi.org/10.1089/lrb.2014.0032
Estimation of limb adiposity by bioimpedance spectroscopy in lymphoedema
Ward, Leigh, Essex, T., Gaw, R., Czerniec, Sharon, Dylke, Elizabeth, Abell, B. and Kilbreath, Sharon. (2013). Estimation of limb adiposity by bioimpedance spectroscopy in lymphoedema. Journal of Physics: Conference Series. 434(1), pp. 1 - 4. https://doi.org/10.1088/1742-6596/434/1/012062
Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy
Ward, L., Dylke, E., Phty, M., Czerniec, S., Isenring, E. and Kilbreath, S.. (2011). Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 43 - 46. https://doi.org/10.1089/lrb.2010.0024
Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy
Ward, Leigh, Dylke, Elizabeth, Czerniec, Sharon Anne, Isenring, Elisabeth and Kilbreath, Sharon. (2011). Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 47 - 51. https://doi.org/10.1089/lrb.2010.0014
Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema
Lee, Mi-Joung, Boland, Robert, Czerniec, Sharon Anne and Kilbreath, Sharon. (2011). Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema. Lymphatic Research and Biology. 9(1), pp. 13 - 18. https://doi.org/10.1089/lrb.2010.0021
Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy
Ward, Leigh, Dylke, Elizabeth, Czerniec, Sharon Anne, Isenring, Elisabeth and Kilbreath, Sharon. (2011). Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 43 - 46. https://doi.org/10.1089/lrb.2010.0024
Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy
Ward, Leigh, Dylke, Elizabeth, Czerniec, Sharon, Isenring, Elisabeth and Kilbreath, Sharon. (2011). Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 47 - 51. https://doi.org/10.1089/lrb.2010.0014
Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
Czerniec, Sharon Anne, Ward, Leigh, Lee, Mi-Joung, Refshauge, Kathryn, Beith, Jane and Kilbreath, Sharon. (2011). Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy. Supportive Care in Cancer. 19(5), pp. 703 - 710. https://doi.org/10.1007/s00520-010-0896-8
Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
Czerniec, Sharon, Ward, Leigh, Lee, Mi-Joung, Refshauge, Kathryn, Beith, Jane and Kilbreath, Sharon. (2011). Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy. Supportive Care in Cancer. 19(5), pp. 703 - 710. https://doi.org/10.1007/s00520-010-0896-8
Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema
Lee, Mi-Joung, Boland, Robert, Czerniec, Sharon and Kilbreath, Sharon. (2011). Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema. Lymphatic Research and Biology. 9(1), pp. 13 - 18. https://doi.org/10.1089/lrb.2010.0021
Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy
Ward, Leigh, Winall, Ann, Isenring, Elisabeth, Hills, Andrew, Czerniec, Sharon Anne, Dylke, Elizabeth and Kilbreath, Sharon. (2011). Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy. International Journal of Gynecological Cancer. 21(2), pp. 409 - 418. https://doi.org/10.1097/IGC.0b013e31820866e1