Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods
Journal article
Fazlollahi, Amir, Bourgeat, Pierrick, Liang, Xiaoyun, Meriaudeau, Fabrice, Connelly, Alan, Salvado, Olivier and Calamante, Fernando. (2015). Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods. NeuroImage. 117, pp. 191 - 201. https://doi.org/10.1016/j.neuroimage.2015.05.048
Authors | Fazlollahi, Amir, Bourgeat, Pierrick, Liang, Xiaoyun, Meriaudeau, Fabrice, Connelly, Alan, Salvado, Olivier and Calamante, Fernando |
---|---|
Abstract | Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To further improve the SNR for pseudo-continuous ASL (PCASL) by accounting for errors in tagging efficiency, the data from multiphase (MP) acquisitions were analyzed using a novel weighted-averaging scheme. The performances of each step in terms of SNR and reproducibility were evaluated using test–retest ASL data acquired from 12 young healthy subjects. The proposed processing pipeline was shown to improve the within-subject coefficient of variation and regional reproducibility by 17% and 16%, respectively, compared to CBF maps computed following motion correction but without the other processing steps. The CBF measurements of MP-PCASL compared to PCASL had on average 23% and 10% higher SNR and reproducibility, respectively. |
Keywords | arterial spin labeling; multiphase pseudo-continuous arterial; spin labeling; perfusion MRI; cerebral blood flow; test–retest; reproducibility |
Year | 2015 |
Journal | NeuroImage |
Journal citation | 117, pp. 191 - 201 |
Publisher | Elsevier B.V. |
ISSN | 1053-8119 |
Digital Object Identifier (DOI) | https://doi.org/10.1016/j.neuroimage.2015.05.048 |
Scopus EID | 2-s2.0-84936741410 |
Page range | 191 - 201 |
Research Group | Mary MacKillop Institute for Health Research |
Publisher's version | File Access Level Controlled |
Place of publication | United States of America |
https://acuresearchbank.acu.edu.au/item/8v082/reproducibility-of-multiphase-pseudo-continuous-arterial-spin-labeling-and-the-effect-of-post-processing-analysis-methods
Restricted files
Publisher's version
100
total views0
total downloads1
views this month0
downloads this month