Estimation of Arm Adipose Tissue Quotient Using Segmental Bioimpedance Spectroscopy

Journal article


Ruben Buendia, T. Essex, Sharon Kilbreath, Sharon Czerniec, Elizabeth Dylke and Leigh C. Ward. (2018). Estimation of Arm Adipose Tissue Quotient Using Segmental Bioimpedance Spectroscopy. Lymphatic Research and Biology. 16(4), pp. 377-384. https://doi.org/10.1089/lrb.2017.0050
AuthorsRuben Buendia, T. Essex, Sharon Kilbreath, Sharon Czerniec, Elizabeth Dylke and Leigh C. Ward
Abstract

Background: Breast cancer-related lymphedema (BCRL) is a chronic condition characterized by accumulation of lymph fluid that may subsequently become fibrotic with infiltration of adipose tissue. Bioimpedance spectroscopy (BIS) is the preferred method for early detection of lymphedema as it can estimate extracellular lymph fluid. This study developed a modified impedance technique that concurrently estimates both lymph accumulation and increases in adipose tissue.

Methods and Results: BIS was used to estimate the adipose tissue volume in a cohort of healthy women (n = 171), which was found to be highly correlated (r > 0.87) with measurements of adipose tissue obtained using the reference method of dual-energy X-ray absorptiometry (DXA). In a separate cohort of women with BCRL (n = 16), adipose volumes measured by BIS and reference method, respectively, were 2452.9 ± 933.3 mL and 2109.1 ± 824 6 mL for affected arms; 1770.9 ± 747.8 mL and 1801.4 ± 775.7 mL for unaffected arms; and comparable values for a group of age-matched controls were 1862.5 ± 661.6 mL and 1657.0 ± 641.1 mL for age-matched control arms. The increase in adipose tissue in affected arms was significant irrespective of the method of measurement, p < 0.02 and p < 0.001 for BIS and DXA, respectively.

Conclusions: An impedance method is described that can estimate increase both in lymph accumulation and adipose tissue in breast cancer-related lymphedema.

Keywordsbioimpedance spectroscopy; BIS; adiposity quotient
Year2018
JournalLymphatic Research and Biology
Journal citation16 (4), pp. 377-384
PublisherMary Ann Liebert, Inc.
ISSN1539-6851
Digital Object Identifier (DOI)https://doi.org/10.1089/lrb.2017.0050
Scopus EID2-s2.0-85052227676
Publisher's version
File Access Level
Controlled
Publication process dates
Deposited11 May 2021
Permalink -

https://acuresearchbank.acu.edu.au/item/8w035/estimation-of-arm-adipose-tissue-quotient-using-segmental-bioimpedance-spectroscopy

Restricted files

Publisher's version

  • 67
    total views
  • 0
    total downloads
  • 3
    views this month
  • 0
    downloads this month
These values are for the period from 19th October 2020, when this repository was created.

Export as

Related outputs

Does lymphedema severity affect quality of life? Simple question. Challenging answers
Teresa S. Lee, Carol M. Morris, Sharon Czerniec and Andrea J. Mangion. (2018). Does lymphedema severity affect quality of life? Simple question. Challenging answers. Lymphatic Research and Biology. 16(1), pp. 85-91. https://doi.org/10.1089/lrb.2016.0049
A patient-based self-examination survey for staging the severity of lymphoedema
Morris, Carol M., Lee, Teresa S., Czerniec, Sharon A. and Mangion, Andrea J.. (2017). A patient-based self-examination survey for staging the severity of lymphoedema. Journal of Lymphoedema. 12(1), pp. 10 - 15.
Breast Cancer-Related Arm Lymphedema: Fluctuation over Six Months and the Effect of the Weather
Czerniec, Sharon Anne, Ward, Leigh and Kilbreath, Sharon. (2016). Breast Cancer-Related Arm Lymphedema: Fluctuation over Six Months and the Effect of the Weather. Lymphatic Research and Biology. 14(3), pp. 148 - 155. https://doi.org/10.1089/lrb.2015.0030
Assessment of segmental arm soft tissue composition in breast cancer-related lymphedema : A pilot study using dual energy X-ray absorptiometry and bioimpedance spectroscopy
Czerniec, Sharon Anne, Ward, Leigh, Meerkin, Jarrod and Kilbreath, Sharon. (2015). Assessment of segmental arm soft tissue composition in breast cancer-related lymphedema : A pilot study using dual energy X-ray absorptiometry and bioimpedance spectroscopy. Lymphatic Research and Biology. 13(1), pp. 33 - 39. https://doi.org/10.1089/lrb.2014.0033
Assessment of breast cancer-related lymphedema : A comparison of moisture meter and spot bioimpedance measurement
Czerniec, Sharon Anne, Ward, Leigh and Kilbreath, Sharon. (2015). Assessment of breast cancer-related lymphedema : A comparison of moisture meter and spot bioimpedance measurement. Lymphatic Research and Biology. 13(1), pp. 10 - 19. https://doi.org/10.1089/lrb.2014.0032
Estimation of limb adiposity by bioimpedance spectroscopy in lymphoedema
Ward, Leigh, Essex, T., Gaw, R., Czerniec, Sharon, Dylke, Elizabeth, Abell, B. and Kilbreath, Sharon. (2013). Estimation of limb adiposity by bioimpedance spectroscopy in lymphoedema. Journal of Physics: Conference Series. 434(1), pp. 1 - 4. https://doi.org/10.1088/1742-6596/434/1/012062
Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy
Ward, Leigh, Winall, Ann, Isenring, Elizabeth, Hills, Andrew, Czerniec, Sharon, Dylke, Elizabeth and Kilbreath, Sharon. (2011). Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy. International Journal of Gynecological Cancer. 21(2), pp. 409 - 418. https://doi.org/10.1097/IGC.0b013e31820866e1
Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy
Ward, L., Dylke, E., Phty, M., Czerniec, S., Isenring, E. and Kilbreath, S.. (2011). Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 43 - 46. https://doi.org/10.1089/lrb.2010.0024
Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy
Ward, Leigh, Dylke, Elizabeth, Czerniec, Sharon Anne, Isenring, Elisabeth and Kilbreath, Sharon. (2011). Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 47 - 51. https://doi.org/10.1089/lrb.2010.0014
Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema
Lee, Mi-Joung, Boland, Robert, Czerniec, Sharon Anne and Kilbreath, Sharon. (2011). Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema. Lymphatic Research and Biology. 9(1), pp. 13 - 18. https://doi.org/10.1089/lrb.2010.0021
Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy
Ward, Leigh, Dylke, Elizabeth, Czerniec, Sharon Anne, Isenring, Elisabeth and Kilbreath, Sharon. (2011). Reference ranges for assessment of unilateral lymphedema in legs by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 43 - 46. https://doi.org/10.1089/lrb.2010.0024
Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy
Ward, Leigh, Dylke, Elizabeth, Czerniec, Sharon, Isenring, Elisabeth and Kilbreath, Sharon. (2011). Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy. Lymphatic Research and Biology. 9(1), pp. 47 - 51. https://doi.org/10.1089/lrb.2010.0014
Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
Czerniec, Sharon Anne, Ward, Leigh, Lee, Mi-Joung, Refshauge, Kathryn, Beith, Jane and Kilbreath, Sharon. (2011). Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy. Supportive Care in Cancer. 19(5), pp. 703 - 710. https://doi.org/10.1007/s00520-010-0896-8
Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
Czerniec, Sharon, Ward, Leigh, Lee, Mi-Joung, Refshauge, Kathryn, Beith, Jane and Kilbreath, Sharon. (2011). Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy. Supportive Care in Cancer. 19(5), pp. 703 - 710. https://doi.org/10.1007/s00520-010-0896-8
Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema
Lee, Mi-Joung, Boland, Robert, Czerniec, Sharon and Kilbreath, Sharon. (2011). Reliability and concurrent validity of the perometer for measuring hand volume in women with and without lymphedema. Lymphatic Research and Biology. 9(1), pp. 13 - 18. https://doi.org/10.1089/lrb.2010.0021
Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy
Ward, Leigh, Winall, Ann, Isenring, Elisabeth, Hills, Andrew, Czerniec, Sharon Anne, Dylke, Elizabeth and Kilbreath, Sharon. (2011). Assessment of bilateral limb lymphedema by bioelectrical impedance spectroscopy. International Journal of Gynecological Cancer. 21(2), pp. 409 - 418. https://doi.org/10.1097/IGC.0b013e31820866e1