A novel device using the Nordic hamstring exercise to assess eccentric knee flexor strength: A reliability and retrospective injury study
Journal article
Opar, David, Piatowski, Timothy, Williams, Morgan and Shield, Anthony J.. (2013). A novel device using the Nordic hamstring exercise to assess eccentric knee flexor strength: A reliability and retrospective injury study. Journal of Orthopaedic and Sports Physical Therapy. 43(9), pp. 636 - 640. https://doi.org/10.2519/jospt.2013.4837
Authors | Opar, David, Piatowski, Timothy, Williams, Morgan and Shield, Anthony J. |
---|---|
Abstract | STUDY DESIGN: Reliability and case-control injury study.OBJECTIVES: To determine if a novel device designed to measure eccentric knee flexor strength via the Nordic hamstringexercise displays acceptable test-retest reliability; to determine normative values for eccentric knee flexor strength derived from the device in individuals without a history of hamstringstrain injury (HSI); and to determine if the device can detect weakness in elite athletes with a previous history of unilateral HSI.BACKGROUND: HSI and reinjury are the most common cause of lost playing time in a number of sports. Eccentric knee flexor weakness is a major modifiable risk factor for future HSI. However, at present, there is a lack of easily accessible equipment to assesseccentric knee flexor strength.METHODS: Thirty recreationally active males without a history of HSI completed the Nordic hamstring exercise on the device on 2 separate occasions. Intraclass correlation coefficients, typical error, typical error as a coefficient of variation, and minimal detectable change at a 95% confidence level were calculated. Normative strength data were determined using the most reliable measurement. An additional 20 elite athletes with a unilateral history of HSI within the previous 12 months performed the Nordic hamstring exercise on the device to determine if residual eccentric muscle weakness existed in the previously injured limb.RESULTS: The device displayed high to moderate reliability (intraclass correlation coefficient = 0.83-0.90; typical error, 21.7-27.5 N; typical error as a coefficient of variation, 5.8%-8.5%; minimal detectable change at a 95% confidence level, 60.1-76.2 N). Mean ± SD normative eccentric flexor strength in the uninjured group was 344.7 ± 61.1 N for the left and 361.2 ± 65.1 N for the right side. The previously injured limb was 15% weaker than the contralateral uninjured limb (mean difference, 50.3 N; 95% confidence interval: 25.7, 74.9; P<.01), 15% weaker than the normative left limb (mean difference, 50.0 N; 95% confidence interval: 1.4, 98.5; P = .04), and 18% weaker than the normative right limb (mean difference, 66.5 N; 95% confidence interval: 18.0, 115.1; P<.01). CONCLUSION: The experimental device offers a reliable method to measure eccentric knee flexor strength and strength asymmetry and to detect residual weakness in previously injured elite athletes. |
Keywords | dynamometry; hamstring; strain injury |
Year | 2013 |
Journal | Journal of Orthopaedic and Sports Physical Therapy |
Journal citation | 43 (9), pp. 636 - 640 |
ISSN | 0190-6011 |
Digital Object Identifier (DOI) | https://doi.org/10.2519/jospt.2013.4837 |
Scopus EID | 2-s2.0-84903965392 |
Open access | Published as green open access |
Page range | 636 - 640 |
Research Group | Sports Performance, Recovery, Injury and New Technologies (SPRINT) Research Centre |
Author's accepted manuscript | License All rights reserved File Access Level Open |
Publisher's version | License All rights reserved File Access Level Controlled |
Supplemental file | License All rights reserved File Access Level Open |
Supplemental file | License All rights reserved File Access Level Open |
https://acuresearchbank.acu.edu.au/item/8v877/a-novel-device-using-the-nordic-hamstring-exercise-to-assess-eccentric-knee-flexor-strength-a-reliability-and-retrospective-injury-study
Download files
Author's accepted manuscript
AM_Opar_2013_A_novel_device_using_the_Nordic.pdf | |
License: All rights reserved | |
File access level: Open |
Supplemental file
0-AM_Opar_2013_A_novel_device_using_the_Nordic_Fig_1.bmp | |
License: All rights reserved | |
File access level: Open |
1-AM_Opar_2013_A_novel_device_using_the_Nordic_Fig_2.bmp | |
License: All rights reserved | |
File access level: Open |
Restricted files
Publisher's version
249
total views817
total downloads0
views this month0
downloads this month