A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data
Journal article
Parker, G. D., Marshall, David, Rosin, P. L., Drage, N., Richmond, S. and Jones, Derek Kenton. (2013). A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data. NeuroImage. 65, pp. 433 - 448. https://doi.org/10.1016/j.neuroimage.2012.10.022
Authors | Parker, G. D., Marshall, David, Rosin, P. L., Drage, N., Richmond, S. and Jones, Derek Kenton |
---|---|
Abstract | Diffusion weighted ( DW ) MRI facilitates non-invasive quantification of tissue microstructure and, in combination with appropriate signal processing, three-dimensional estimates of fibrous orientation. In recent years, attention has shifted from the diffusion tensor model, which assumes a unimodal Gaussian diffusion displacement profile to recover fibre orientation ( with various well-documented limitations ), towards more complex high angular resolution diffusion imaging ( HARDI ) analysis techniques. Spherical deconvolution ( SD ) approaches assume that the fibre orientation density function ( fODF ) within a voxel can be obtained by deconvolving a ‘common’ single fibre response function from the observed set of DW signals. In practice, this common response function is not known a priori and thus an estimated fibre response must be used. Here the establishment of this single-fibre response function is referred to as ‘calibration’. This work examines the vulnerability of two different SD approaches to inappropriate response function calibration: ( 1 ) constrained spherical harmonic deconvolution ( CSHD )—a technique that exploits spherical harmonic basis sets and ( 2 ) damped Richardson–Lucy ( dRL ) deconvolution—a technique based on the standard Richardson–Lucy deconvolution. Through simulations, the impact of a discrepancy between the calibrated diffusion profiles and the observed ( ‘Target’ ) DW-signals in both single and crossing-fibre configurations was investigated. The results show that CSHD produces spurious fODF peaks ( consistent with well known ringing artefacts ) as the discrepancy between calibration and target response increases, while dRL demonstrates a lower over-all sensitivity to miscalibration ( with a calibration response function for a highly anisotropic fibre being optimal ). However, dRL demonstrates a reduced ability to resolve low anisotropy crossing-fibres compared to CSHD. It is concluded that the range and spatial-distribution of expected single-fibre anisotropies within an image must be carefully considered to ensure selection of the appropriate algorithm, parameters and calibration. Failure to choose the calibration response function carefully may severely impact the quality of any resultant tractography. |
Keywords | spherical harmonic deconvolution; Richardson–Lucy; MRI; calibration; tractography; diffusion tensor imaging |
Year | 2013 |
Journal | NeuroImage |
Journal citation | 65, pp. 433 - 448 |
Publisher | Academic Press |
ISSN | 1053-8119 |
Digital Object Identifier (DOI) | https://doi.org/10.1016/j.neuroimage.2012.10.022 |
Scopus EID | 2-s2.0-84868464090 |
Open access | Open access |
Page range | 433 - 448 |
Publisher's version | |
Additional information | © 2012 Elsevier Inc. Open access under CC BY license. |
Place of publication | United States |
https://acuresearchbank.acu.edu.au/item/87z40/a-pitfall-in-the-reconstruction-of-fibre-odfs-using-spherical-deconvolution-of-diffusion-mri-data
Download files
122
total views93
total downloads1
views this month0
downloads this month